DC blowers move air in a centrifugal direction - drawing it in axially and exhausting it radially - making them the right choice when static pressure matters as much as airflow volume. Unlike axial fans, which move air straight through, DC blowers are built for applications where air needs to be pushed through ducting, filters, or restricted pathways. Brushless DC motor technology means precise speed control, long service life, and reliable performance across a wide voltage range without the complexity of AC power conversion.

Browse our selection of DC blowers below, or contact YS Tech USA if you need a custom solution engineered to your specifications.

BW05115005BL
50
15
5 (VDC)
4~5.5
4500
3.9
12
170
0.85
80000
37.5
BW05115005BM
50
15
5 (VDC)
4~5.5
5500
4.7
16.2
350
1.75
80000
42
BW05115012BL
50
15
12 (VDC)
7~13.2
4500
3.9
12
95
1.14
80000
37.5
BW05115012BM
50
15
12 (VDC)
7~13.2
5500
4.7
16.2
160
1.92
80000
42
BW05115012BH
50
15
12 (VDC)
7~13.2
6500
5.5
20.9
230
2.76
80000
45.5
BW05115012BS
50
15
12 (VDC)
7~13.2
7500
6.3
26.2
290
3.48
75000
48.5
BW05115012LL
50
15
12 (VDC)
7~13.2
4500
3.9
12
100
1.2
65000
37.5
BW05115012LM
50
15
12 (VDC)
7~13.2
5500
4.7
16.2
150
1.8
50000
42
BW05115012LH
50
15
12 (VDC)
7~13.2
6500
5.5
20.9
220
2.64
50000
45.5
BW05115012LS
50
15
12 (VDC)
7~13.2
7500
6.3
26.2
290
3.48
50000
48.5
BW05115024BL
50
15
24 (VDC)
12~26.4
4500
3.9
12
60
1.44
80000
37.5
BW05115024BM
50
15
24 (VDC)
12~26.4
5500
4.7
16.2
85
2.04
80000
42
BW05115024BH
50
15
24 (VDC)
12~26.4
6500
5.5
20.9
120
2.88
75000
45.5
BW05115024BS
50
15
24 (VDC)
12~26.4
7500
6.3
26.2
180
4.32
65000
48.5
BW06018012BL
60
18
12 (VDC)
7~13.2
4200
6.7
17.6
140
1.68
80000
38
BW06018012BM
60
18
12 (VDC)
7~13.2
4800
7.7
21.2
180
2.16
80000
43.5
BW06018012BH
60
18
12 (VDC)
7~13.2
5400
8.2
22
280
3.36
75000
49
BW060250 1 2BL
60
25
12 (VDC)
7~13.2
3000
6.5
6.1
110
1.32
80000
31.5
BW06025012BM
60
25
12 (VDC)
7~13.2
3700
8.1
8.4
180
2.16
80000
35.8
BW06025012BH
60
25
12 (VDC)
7~13.2
4500
10.6
15.3
230
2.76
75000
41
BW06025024BL
60
25
24 (VDC)
12~26.4
3000
6.5
6.1
45
1.08
80000
31.5
BW06025024BM
60
25
24 (VDC)
12~26.4
3700
8.1
8.4
70
1.68
80000
35.8
BW06025024BH
60
25
24 (VDC)
12~26.4
4500
10.6
15.3
110
2.64
75000
41
BW080300 1 2BL
80
30
12 (VDC)
7~13.2
2400
9.7
5.5
110
1.32
80000
37
BW08030012BM
80
30
12 (VDC)
7~13.2
3000
12.2
10.3
190
2.28
80000
42
BW08030012BH
80
30
12 (VDC)
7~13.2
3400
14
13.7
270
3.24
75000
44.5
BW08030012BS
80
30
12 (VDC)
7~13.2
4000
16.5
20.3
360
4.32
65000
48
BW08030012BSS
80
30
12 (VDC)
7~13.2
4200
17.5
21.8
430
5.16
65000
49.5
BW08030012SL
80
30
12 (VDC)
7~13.2
2300
9.3
5.1
180
2.16
30000
36
BW08030012SM
80
30
12 (VDC)
7~13.2
2900
11.8
9.8
210
2.52
30000
41
BW08030012SH
80
30
12 (VDC)
7~13.2
3300
13.6
13.1
300
3.6
25000
43.5
BW0803002 4BL
80
30
24 (VDC)
12~26.4
2400
9.7
5.5
60
1.44
80000
37
BW08030024BM
80
30
24 (VDC)
12~26.4
3000
12.2
10.3
110
2.64
80000
42
BW08030024BH
80
30
24 (VDC)
12~26.4
3400
14
13.7
150
3.6
75000
44.5
BW08030024BS
80
30
24 (VDC)
12~26.4
4000
16.5
20.3
200
4.8
65000
48
BW08030024SL
80
30
24 (VDC)
12~26.4
2400
9.7
5.5
110
2.64
30000
37
BW08030024SM
80
30
24 (VDC)
12~26.4
3000
12.2
10.3
150
3.6
30000
42
BW08030024SH
80
30
24 (VDC)
12~26.4
3400
14
13.7
190
4.56
25000
44.5
BW09733012BL
97
33
12 (VDC)
7~13.2
2600
25.6
22.1
400
4.8
80000
40
BW09733012BM
97
33
12 (VDC)
7~13.2
2900
28.5
24.7
480
5.76
80000
42.5
BW09733012BH
97
33
12 (VDC)
7~13.2
3300
32.4
28.1
740
8.88
75000
48.5
BW09733012BS
97
33
12 (VDC)
7~13.2
3700
42.6
29.4
850
10.2
65000
53
BW09733012BJ
97
33
12 (VDC)
7~13.2
4500
25.6
56
1400
16.8
65000
58
BW09733024BL
97
33
24 (VDC)
12~26.4
2600
28.5
22.1
210
5.04
80000
40
BW09733024BM
97
33
24 (VDC)
12~26.4
2900
32.4
24.7
280
6.72
80000
42.5
BW09733024BH
97
33
24 (VDC)
12~26.4
3300
42.6
28.1
420
10.08
75000
48.5
BW09733024BS
97
33
24 (VDC)
12~26.4
3700
34.2
29.4
400
9.6
65000
53
BW09733024BJ
97
33
24 (VDC)
12~26.4
4500
42.6
56
680
16.32
65000
58
BW09733024BV
97
33
24 (VDC)
12~26.4
5300
48.9
81.5
1300
31.2
65000
62
BW12032012BL
120
32
12 (VDC)
7~13.2
1700
23
8
150
1.8
80000
42.5
BW12032012BM
120
32
12 (VDC)
7~13.2
2100
29.5
13.8
250
3
80000
49.5
BW12032012BH
120
32
12 (VDC)
7~13.2
2600
37.2
24.7
700
8.4
75000
57
BW12032012BS
120
32
12 (VDC)
7~13.2
2900
41.4
29
900
10.8
65000
59
BW12032012BU
120
32
12 (VDC)
7~13.2
3500
47.5
41.7
1500
18
65000
62
BW12032024BL
120
32
24 (VDC)
12~26.4
1700
23
8
120
2.88
80000
42.5
BW12032024BM
120
32
24 (VDC)
12~26.4
2100
29.5
13.8
180
4.32
80000
49.5
BW12032024BH
120
32
24 (VDC)
12~26.4
2600
37.2
24.7
260
6.24
75000
57
BW12032024BS
120
32
24 (VDC)
12~26.4
2900
41.4
29
450
10.8
65000
59
BW12032024BU
120
32
24 (VDC)
12~26.4
3500
47.5
41.7
830
19.92
65000
62
BW09733012BL-N
97
33
12 (VDC)
7~13.2
4500
37.8
34.7
900
10.8
80000
54.8
BW09733012BM-N
97
33
12 (VDC)
7~13.2
4850
40.7
44.1
1200
14.4
80000
56.7
BW09733012BH-N
97
33
12 (VDC)
7~13.2
5250
44.8
55.8
1600
19.2
75000
58.4
BW09733012BS-N
97
33
12 (VDC)
7~13.2
5750
48.2
86.6
2700
32.4
65000
60.6
BW09733012BJ-N
97
33
12 (VDC)
7~13.2
6850
58.4
139.6
4200
50.4
65000
64.8
BW09733024BL-N
97
33
24 (VDC)
12~26.4
4500
37.8
34.7
500
12
80000
54.8
BW09733024BM-N
97
33
24 (VDC)
12~26.4
4850
40.7
44.1
600
14.4
80000
56.7
BW09733024BH-N
97
33
24 (VDC)
12~26.4
5250
44.8
55.8
800
19.2
75000
58.4
BW09733024BS-N
97
33
24 (VDC)
12~26.4
5750
48.2
86.6
1200
28.8
65000
60.6
BW09733024BJ-N
97
33
24 (VDC)
12~26.4
6850
58.4
139.6
2000
48
65000
64.8
QV113341HBL-7A3
133
120 (VAC)
100~140
5330
280
95.504
1.23
85
60000
72.3
QV117542HBL-7A3
175
120 (VAC)
100~140
4500
449
88.138
1.51
108
60000
75.2
QV119045HBL-7A3
190
120 (VAC)
100~140
3750
477
100.33
1.58
120
60000
73.6
QV122563HBL-7A3
225
120 (VAC)
100~140
2900
571
56.134
1.07
130
60000
70.3
QV1310A0MBL-9A2
310
120 (VAC)
100~140
1500
1416
61.468
1.87
130
60000
66
QV213341HBL-7A2
133
230 (VAC)
200~240
5920
289
97.536
0.95
108
60000
74.3
QV217542HBL-7A2
175
230 (VAC)
200~240
4460
458
89.916
0.95
110
60000
75.2
QV219045HBL-7A2
190
230 (VAC)
200~240
3590
446
105.41
0.91
106
60000
72.3
QV222563HBL-7A2
225
230 (VAC)
200~240
2500
566
55.118
0.67
70
60000
66.1
QV222563HBL-9A2
225
230 (VAC)
200~240
3400
931
106
0.85
200
60000
74.5
QV225057MBL-9A2
250
230 (VAC)
200~240
2700
973
91.84
1.74
200
60000
72
QV228080MBL-9A2
280
230 (VAC)
200~240
2300
1448
91.84
1.74
200
60000
72
QV2310A0MBL-9A2
310
230 (VAC)
200~240
1500
1416
61.468
1.25
130
60000
66
WV113362HBL-7A2
133
120 (VAC)
100~140
2820
285
72.4
1.23
73
60000
61.5
WV114059HBL-7A2
140
120 (VAC)
100~140
2700
290
75
1.24
75
60000
62.7
WV210851HBL-7A2
108
230 (VAC)
200~240
4400
218
101.092
0.96
70
60000
68
WV212061HBL-7A2
120
230 (VAC)
200~240
3450
279
99.682
0.95
77
60000
64.7
WV213362HBL-7A2
133
230 (VAC)
200~240
2890
322
91.948
0.94
78
60000
63.9
WV214059HBL-7A2
140
230 (VAC)
200~240
2750
321
98.806
0.97
77
60000
61.2
WV216062HBL-9A2
160
230 (VAC)
200~240
2150
405
94.996
1.74
195
60000
60.9
WV218092HBL-9A2
180
230 (VAC)
200~240
1200
616
81.28
1.55
180
60000
51.2
No results matched the selected filters.
90 Results

Choose the right blower for your needs:

backward curved

Backward Curved EC

forward curved

Forward Curved EC

dc blower

DC Blowers

What is a DC blower?

A DC blower is a centrifugal fan powered by a brushless direct current motor. It draws air in through an inlet at the center of the impeller and discharges it radially at 90 degrees to the intake, building static pressure as it moves air through the system. This makes DC blowers well-suited for applications where airflow must overcome resistance from filters, ducting, heat exchangers, or restricted enclosures.

What is the difference between a DC blower and a DC axial fan?

A DC axial fan moves air parallel to its rotational axis - straight through the fan - and is optimized for high airflow volume at low static pressure. A DC blower moves air at 90 degrees to the intake and is optimized for applications requiring higher static pressure. When an application involves restricted airflow paths or ducted systems, a blower is typically the more effective choice.

What are DC blowers used for?

DC blowers are used across a wide range of applications including medical devices, industrial control enclosures, telecommunications equipment, CPAP and respiratory systems, laser cooling, and AI/high-compute hardware. Any application where airflow needs to be directed through a confined path or pushed against back pressure is a candidate for a centrifugal blower rather than an axial fan.

What voltage options are available for DC blowers?

DC blowers are available in a range of operating voltages - commonly 5V, 12V, 24V, and 48V - to match the power supply of the target system. Brushless DC motors also support variable-speed control via a PWM signal, allowing airflow to be dynamically tuned based on thermal load without requiring external controllers.

How do I choose the right DC blower for my application?

The two primary performance parameters are airflow (measured in CFM or m³/h) and static pressure (measured in inches H₂O or Pa). Start by identifying the airflow volume your application requires and the static pressure your system will impose - from ducting, filters, or enclosure geometry. From there, select a blower whose performance curve intersects your system resistance curve within the operating range. Contact YS Tech USA if you need application engineering support selecting the right unit.

What size DC blowers does YS Tech USA offer?

YS Tech USA offers DC blowers in multiple frame sizes to cover a range of airflow and static pressure requirements. Use the filters above to narrow by size and performance, or contact YS Tech USA if your application requires a custom configuration.

Make a Request for Quotation